1. Automatic protection from overcurrent, overheat, over/under voltage
2. Easy to start arc, arc stably and heat concentrated
3. Peak/bottom value fo pulse, pulse frequency, pulse duty cycle and maintaining current all adjustable
4. Support DC TIG welding, pulse TIG welding and MMA welding
5. With all functions of WS7 series

 | WSM7-400 | |
Power source | 3-phase 380V/415V/220V 50Hz | |
Rated input capacity | 17.3KVA | |
Rated input current | 26.3A | |
Rated welding current | 400A | |
Welding current | 400A 60%DE | |
315AÂ 100%DE | ||
Adjustment range of current | 20-400A | |
Efficiency | 83% | |
No-load voltage | TIG | 40-50V |
MMA | 70-80V | |
Current up/down-slope time | 0-10S | |
Time for pre-gas sending | 1S | |
Time for delay gas sending | 5S | |
Arc-start means | HF |
1. Automatic protection from overcurrent, overheat, over/under voltage
2. Easy to start arc, arc stably and heat concentrated
3. Peak/bottom value fo pulse, pulse frequency, pulse duty cycle and maintaining current all adjustable
4. Support DC TIG welding, pulse TIG welding and MMA welding
5. With all functions of WS7 series

 | WSM7-400 | |
Power source | 3-phase 380V/415V/220V 50Hz | |
Rated input capacity | 17.3KVA | |
Rated input current | 26.3A | |
Rated welding current | 400A | |
Welding current | 400A 60%DE | |
315AÂ 100%DE | ||
Adjustment range of current | 20-400A | |
Efficiency | 83% | |
No-load voltage | TIG | 40-50V |
MMA | 70-80V | |
Current up/down-slope time | 0-10S | |
Time for pre-gas sending | 1S | |
Time for delay gas sending | 5S | |
Arc-start means | HF |
Metal Body Square Water Cooling Tower
This series of products run stable, low noise, energy-saving, in office buildings, shopping malls, hotels, residential areas and other central air-conditioning supporting the use of better results.
The company's standard cooling tower according to the international design conditions design, can also provide customers with non-standard operating conditions or specific sizes under the special, special design.
The circulating water pump suction port shall be located below the water level of the cooling tower catchment basin, and the cooling tower outlet pipe shall not be allowed to be higher than the maximum water level of the catchment basin.
Pipe mounts should be pipe racks and cooling towers should not be allowed to directly bear the weight of the pipes.
The rehydration pipe of the cooling tower should be provided with a support stand to avoid vibration of the pipe when the float valve is rehydrated.
Rehydration pressure should be below 5m water pressure, national standard
The flannage pressure is 1.0Mpa.
When two or more units are assembled, our company will provide a connecting balance tube to balance the chassis water level. The tower top inlet should be set with a conditioning valve in order to enter each
.The water level of the tower is uniform.
The noise is measured at dm1.13VL-W at the equivalent diameter of the cooling tower (Dm1.13VL*W), 1.5 meters above the ground height, wherein L and W are the shape rulers of the tower
inch long and wide).
The use of cellular continuous blister series of diversion,heat dissipation, water collection three-in-one native filler, the whole suspension, gravity cloth water, low drop of water, with cold effect
High, low energy consumption, less drift water, less noise and so on, floating water rate is less than 0.001%.
When connecting different types of towers, the bottom basin water level height of different types of towers must be taken into account, and the base height must be adjusted to maintain the water level balance of the towers.
Metal Body Square Water Cooling Tower,Tower Water Cooler,Water Cooled Cooling Tower,Tower Cooling System
Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhouarkfluid.com