1. Application Conditions:
Â
The LQDL (F) pump is designed for conveying cold and hot cleaning water with temperatures ranging from -30°C to +150°C or non-flammable and non-explosive liquids that are free of solid particles or fibers. The maximum ambient temperature is +40°C.
Â
Â
2. Performance Parameters:
Â
Flow Q= 1.0~180 m³/h
Head H= 7~268 m
Rev n=2950 r/min
Power P=0.37~75 kw
Inlet diameter Dna=25~125mm
Allowable working pressure ≤25~40 bar
Rated frequency: 50 Hz or 60 Hz
Â
Â
3. Advantages:
Â
Those with "F" indicate corrosion resistance
Compact design
High efficiency
Low vibration
Easy maintenance
Â
Â
4. Applications:
Â
Circulation pressure boosting
Water filtration in water treatment plants
Residential water supply
Firefighting systems
Air conditioning units
Fault Phenomenon | Failure Cause | Elimination Methods |
 | 1. No power supply or one or two phase power supply is needed |
Check all phases of power supply and restore power supply  |
 | 2. Poor contact of ac contactor and burning of coil |
Repair or replace contactors  |
Can not start |
3. The power switch is not closed, malfunction or damaged  |
Close the switch and replace it if the power indicator does not turn on |
 |
4. Thermal relay trip or damage  |
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started |
 | Water level is too low |
Put water in the sink  |
 | The motor burned |
Repair or replace the motor  |
 | 1. Line is loose |
Check wiring and tighten connectors  |
 | 2. Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. |
The manual is normal | 3. The frequency converter is damaged | Repair or replace |
Automatic transmission failure | 4. Pressure switch damage | Repair or replace |
 | 5. The pressure transmitter is damaged | Repair or replace |
 | 6. Switch failure | Repair or replace |
Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power  |
Too much flow, impeller wear  |
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |
1.5 Ton Mini Excavator XN16 with Japanese Yanmar engine,different engine models can be meet different market requirements.
Yanmar 3TNV70 -Stage III
Yanmar 3TNV74F :11.2kw -Euro V
Yanmar 3TNV74F :11.2kw -EPA III
Main information for mini excavator XN16:
Net weight 1500 kg,operation weight 1600kg; 0.045 cbm bucket,1.5km/h; 3160x1110x2377mm
Max. digging depth: 2150mm,Max. Digging height:3275mm
EATON swing motor, famouse brand Gear pump, DONGHYUN travelling motor
The 1.5 ton mini excavator have been exported more than 5 years,the excavators also keep upgrading for meet customers's new needs.
The 1.5 ton mini excavator XN16 every years more than 2000 units mini excavators sell in Europe market,1000units sell in Australia market,more than 500 units to US ,Canada market.
1.5 Ton Mini Excavator Machine,Mini Excavator 1.5 Ton,1.5 Ton Small Excavator,1.5 Ton Micro Excavator
SHANDONG KEN STONE HEAVY MACHINERY CO.,LTD , https://www.chinaexcavator.com